Public Facility
Projects
·
Service Club Ballfields, Kent, WA, 2006
Structural design for a (1) story restroom and concession facility of approximately 4,000 ft2
consisting of timber framing for roof, masonry walls, and a conventional continuous concrete
footing.
An open Canopy Roof extended 26’ in height and projected 18’ beyond either side of the
main building. The canopy required special Finite Element Analysis of Wind forces using
StaadPRO and special anchorage to support lateral movement under Wind and Seismic forces.
·
Kent Fenwick Park Restroom Building,
Kent, WA, 2004
New (1) story 1,200 ft2 Building for Restrooms with 9' high masonry walls and an
elevated CIP concrete slab for a planted garden roof with a clear span of 16'.
A section of the building had 18' high masonry walls for equipment storage. Architectural
Concept and Owner's requirement for Equipment Storage were achieved in Seismic Design
Category D using a Horizontal Transfer Girder.
|
Typical Public
Facility Plans and Details
The Plans and Details
shown below were created using AutoCAD 2000.
|
Framing
Plan Sheet
|
|
Structural
Section
|
|
Structural
Detail
|
|